Ricoh MPC03 machine SC362 fault solution

2019-04-01 15:35:58

                                                                Fault solution

Model: Ricoh MPC 03 machine failure (code): SC362-

Author: Choi days Technology Co., Ltd.

Fault phenomenon:

Boot or print report SC362

图片关键词


the reason:

The drum module development chamber TD sensor output value is abnormal (the more the powder amount, the smaller the value)


图片关键词

solution:

1View the maintenance manual

The faults of SC362-1, 2, 3, and 4 correspond to one of the four colors of K, C, M, and Y.

图片关键词

2 Check whether the output value of the TD sensor corresponding to the SP mode 3-210 is lower than the normal value (error will be reported below 0.8V), and execute 3 after lower than the normal value (SP mode 3-210 as shown below)

 

3 Print a full-color map of multiple error-colored drums (the purpose is to reduce the amount of toner in the developer), then enter SP mode 3-030 to do the error color item TD sensor initialization until the TD sensor output value reaches the normal value, fault SC The code is released.

(SP mode 3-030 as shown below)

图片关键词